{ "Product Overview" : { "Environmental Space" : "Indoor - Riser" }, "Physical Characteristics (Overall)" : { "Conductor" : { "AWG" : "5", "Stranding" : "7x30", "Material" : "TC - Tinned Copper", "No. of Pairs" : "1" }, "Conductor Count" : "2", "Conductor Size" : "22 AWG", "Insulation" : { "Material" : "4", "Nominal Diameter" : "0.046 in", "Nominal Wall Thickness" : "0.008 in" }, "Color Chart" : { "Number" : "3", "Color" : "Black & Red" }, "Outer Shield Material" : { "Type" : "5", "Material" : "Aluminum/Polyester", "Material Trade Name" : "Beldfoil®", "Coverage [%]" : "100 %", "Drainwire Material" : "TC - Tinned Copper", "Drainwire AWG" : "22", "Drainwire Construction n x D" : "7x30 mm" }, "Outer Jacket Material" : { "Material" : "4", "Nominal Diameter" : "0.135 in", "Nominal Wall Thickness" : "0.02 in" } }, "Electrical Characteristics" : { "Conductor DCR" : { "Nominal Conductor DCR" : "3", "Nominal Outer Shield DCR" : "14.3 Ohm/1000ft" }, "Capacitance" : { "Nom. Capacitance Conductor to Conductor" : "3", "Nom. Capacitance Conductor to Other Conductor to Shield" : "67 pF/ft" }, "Inductance" : { "Nominal Inductance" : "2" }, "Impedance" : { "Nominal Characteristic Impedance" : "2" }, "Delay" : { "Nominal Delay" : "3", "Nominal Velocity of Propagation (VP) [%]" : "66 %" }, "Current" : { "Max. Recommended Current [A]" : "2" }, "Voltage" : { "UL Voltage Rating" : "2" } }, "Temperature Range" : { "UL Temp Rating" : "60°C", "Operating Temp Range" : "-20°C To +75°C" }, "Mechanical Characteristics" : { "Bulk Cable Weight" : "14 lbs/1000ft", "Max Recommended Pulling Tension" : "27 lbs", "Min Bend Radius/Minor Axis" : "1.5 in" }, "Standards" : { "NEC/(UL) Specification" : "CMR", "CPR Euroclass" : "Eca" }, "Applicable Environmental and Other Programs" : { "EU Directive 2000/53/EC (ELV)" : "Yes", "EU Directive 2003/96/EC (BFR)" : "Yes", "EU Directive 2011/65/EU (ROHS II)" : "Yes", "EU Directive 2012/19/EU (WEEE)" : "Yes", "EU Directive 2015/863/EU" : "Yes", "EU Directive Compliance" : "EU Directive 2003/11/EC (BFR)", "EU CE Mark" : "Yes", "EU RoHS Compliance Date (yyyy-mm-dd)" : "2004-01-01", "CA Prop 65 (CJ for Wire & Cable)" : "Yes", "MII Order #39 (China RoHS)" : "Yes" }, "Suitability" : { "Suitability - Aerial" : "Yes - When supported by messenger wire", "Suitability - Burial" : "No", "Suitability - Hazardous Locations" : "No", "Suitability - Indoor" : "Yes", "Suitability - Outdoor" : "Yes - Black only", "Suitability - Sunlight Resistance" : "No" }, "Flammability, LS0H, Toxicity Testing" : { "UL Flammability" : "UL1666 Vertical Shaft", "CSA Flammability" : "FT4", "UL voltage rating" : "300 V RMS" }, "Plenum/Non-Plenum" : { "Plenum (Y/N)" : "No", "Plenum Number" : "9451P" } } |