{ "Analog Inputs" : { "Number of Inputs" : "None." }, "System" : { "Sampling Rate" : "48 kHz.", "Processors" : "1 x Analog Devices SHARC 21489 @ 400 MHz SIMD.", "Raw Processing Capacity" : "400 MIPS, 1.6 GFLOPS.", "Delay Memory" : "174 mono seconds.", "RS-485 Serial I/O" : "38.4 kbaud (default) 8 data bits, 1 stop bit, no parity, no flow control. May be broken out of ARC port.", "Ethernet Cable" : "Standard CAT5e or CAT6, maximum device-to-device length = 100 meters.", "Dante Cable" : "Standard CAT6, maximum device-to-device length = 100 meters.", "ARC Cable" : "Standard CAT5, distance dependent upon load and number of devices. 8 Watts maximum power available.", "Maximum Devices Per System" : "80 Units per Site File.", "Maximum Stored Presets" : "1000." }, "Analog Outputs" : { "Number of Outputs" : "None." }, "Mechanical Specifications" : { "Space Required" : "Half rack unit (WDH: 20.83 cm x 22.86 cm x 4.37 cm / 8.2 in. x 9 in. x 1.72 in.) Depth does not include connector allowance. Allow at least 3 inches additional clearance for rear panel connections. Additional depth may be required depending upon your specific wiring and connections.", "Electrical" : "PoE+ IEEE 802.3at Class 4, 7 Watts minimum to 25.5 Watts maximum. No line voltage switching required. Note: Subject to change when actual power requirements are determined.", "Ventilation" : "Maximum recommended ambient operating temperature is 30 C / 86 F. Ensure that the left and right equipment sides are unobstructed (5.08 cm, 2 in minimum clearance). The ventilation should not be impeded by covering the ventilation openings with items such as newspapers, tablecloths, curtains, etc.", "Certifications or Compliance" : "Safety: UL 60065, cUL 60065, IEC 60065. EMC: “Class A” device (applies to all of the following) EN 55032, EN 55103-2, EN 61000-3-2, EN 61000-3-3, FCC Part 15, ICES-003. Environmental: RoHS.","Shipping Weight" : "5.2 lbs. (2.4 kg)" } } |